A row of 1960s classrooms faced a narrow service street where delivery trucks idled at midday. The original aluminum windows had single glazing and no shading, so the rooms overheated by ten-thirty each morning. Instead of replacing the entire façade, the district added a new layer of vertical timber screens two feet outside the glass line. The gap between glass and wood now holds a simple steel channel that catches leaves and keeps birds from nesting against the sills.
Each screen panel is eight feet tall and four feet wide, made from rough-sawn Douglas fir two-by-twos screwed to a light frame. The spacing is two and a half inches, enough for a view of the street but narrow enough to break the low winter sun into strips that land on the vinyl tile floor. Teachers say the pattern moves slowly enough that it does not distract during reading time. On overcast days the wood appears almost black against the sky, so the rooms feel enclosed without feeling dark.
The decision to keep the old windows in place changed the construction sequence. Crews worked from swing stages rather than scaffolding inside the rooms. Each panel was lifted by two workers, set on temporary blocks, then fixed with four lag screws into the existing concrete spandrel. The only interior work was the removal of roller shades that were no longer needed. The project finished during spring break; students returned to rooms that were three to four degrees cooler by noon.
Because the screens sit outside the thermal envelope, the fir seasons naturally. After the first winter the faces checked lightly along the grain, but the checks do not go through the thickness. A facilities supervisor checks the fasteners once a year with a cordless drill and a six-inch bit. When a batten loosens, it is swapped from a stack stored under the stage in the auditorium. No paint or sealer has been applied; the wood is allowed to turn silver at its own pace.
On the east elevation the same screen detail was used only above the first-floor windows, where the sun angle is steepest. Below that line, the original brick remains exposed. The change in material at eye level makes the retrofit legible without added labels. Students waiting for buses can reach up and touch the lower edge of the lowest batten, learning the depth of the assembly by feel rather than diagram.
Rain that blows through the gaps lands on the original aluminum frames and evaporates within hours. The small amount of water that reaches the timber helps control checking by keeping the outer fibers from drying too fast. Inside, condensation on the glass has dropped because the screens reduce radiant heat on the surface; custodians report fewer streaks on the panes by mid-afternoon.
The school board had considered perforated metal panels for lower maintenance, but the sample shown at the public meeting felt thin and warm to the touch on a June afternoon. The timber sample stayed cool and gave slightly under pressure from a thumb. That difference settled the material choice.